Fix typo, same config for both projects

This commit is contained in:
Jonathan Jenne 2021-07-28 15:34:46 +02:00
parent 013f46c13d
commit d8081ab122
2 changed files with 6 additions and 22 deletions

View File

@ -21,9 +21,7 @@ Module Module1
oReturnResult = CODE_SUCCESS
' Console.WriteLine("Starting up WIDig...")
Dim opath = Environment.GetFolderPath(Environment.SpecialFolder.LocalApplicationData)
Dim oLogConfig As New LogConfig(LogConfig.PathType.AppData, Nothing, Nothing,
"Digital Data",
"WIDig")
Dim oLogConfig As New LogConfig(LogConfig.PathType.AppData, Nothing, "Console", "Digital Data", "WIDig")
LOGCONFIG = oLogConfig
LOGGER = LOGCONFIG.GetLogger
@ -34,7 +32,7 @@ Module Module1
System.Console.WriteLine($"Starting up WIDig...")
If Connect2Windream(oUserPW) = True Then
If Connect2Windream(oUserPW) = False Then
Throw New ApplicationException("Could not initialize windream")
End If
@ -82,17 +80,9 @@ Module Module1
End Function
Public Sub InitUserConfig()
Dim oProgramDataPath = Path.Combine(Environment.GetFolderPath(Environment.SpecialFolder.CommonApplicationData), "Digital Data", "WIDig")
Dim oUserAppDataPath = Path.Combine(Environment.GetFolderPath(Environment.SpecialFolder.ApplicationData), "Digital Data", "WIDig")
CONFIG = New ConfigManager(Of ClassConfig)(LOGCONFIG, oUserAppDataPath, oProgramDataPath)
'oUserAppDataPath = oUserAppDataPath & "\Digital Data\WIDigDat"
'Dim oCommonAppDataPath = Path.GetDirectoryName(System.Reflection.Assembly.GetExecutingAssembly().Location)
'CONFIG = New ConfigManager(Of ClassConfig)(LOGCONFIG, oUserAppDataPath, System.AppDomain.CurrentDomain.BaseDirectory, oCommonAppDataPath)
'System.Console.WriteLine($"Config loaded!")
'LOGGER.Info("Config loaded")
'Settings_Load()
End Sub
Public Function InitDatabase() As Boolean
If CONFIG.Config.ConnectionString.Length = 0 Then

View File

@ -8,11 +8,7 @@ Public Class frmMain
Try
Me.Hide()
Me.Visible = False
Dim oLogConfig As New LogConfig(LogConfig.PathType.CustomPath,
Application.LocalUserAppDataPath & "\Log",
Nothing,
My.Application.Info.CompanyName,
My.Application.Info.ProductName)
Dim oLogConfig As New LogConfig(LogConfig.PathType.AppData, Nothing, "Form", "Digital Data", "WIDig")
LOGCONFIG = oLogConfig
LOGGER = LOGCONFIG.GetLogger
@ -55,11 +51,9 @@ Public Class frmMain
End Sub
Public Sub InitUserConfig()
CONFIG = New ConfigManager(Of ClassConfig)(LOGCONFIG, Application.UserAppDataPath, Application.CommonAppDataPath, Application.StartupPath)
LOGGER.Info("Config loaded")
'Settings_Load()
Dim oProgramDataPath = IO.Path.Combine(Environment.GetFolderPath(Environment.SpecialFolder.CommonApplicationData), "Digital Data", "WIDig")
Dim oUserAppDataPath = IO.Path.Combine(Environment.GetFolderPath(Environment.SpecialFolder.ApplicationData), "Digital Data", "WIDig")
CONFIG = New ConfigManager(Of ClassConfig)(LOGCONFIG, oUserAppDataPath, oProgramDataPath)
End Sub
Private Function Connect2Windream(oPW As String)
Try