This commit is contained in:
2023-07-20 14:12:24 +02:00
parent c2deb54f11
commit ea5ea5f205
64 changed files with 8139 additions and 7996 deletions

View File

@@ -908,6 +908,8 @@ Partial Public Class DD_ECMAdmin
Private columnLANGUAGE As Global.System.Data.DataColumn
Private columnNODE_NAVIGATION As Global.System.Data.DataColumn
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Sub New()
@@ -1023,6 +1025,14 @@ Partial Public Class DD_ECMAdmin
End Get
End Property
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public ReadOnly Property NODE_NAVIGATIONColumn() As Global.System.Data.DataColumn
Get
Return Me.columnNODE_NAVIGATION
End Get
End Property
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0"), _
Global.System.ComponentModel.Browsable(false)> _
@@ -1060,9 +1070,9 @@ Partial Public Class DD_ECMAdmin
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Overloads Function AddTBPMO_FORM_CONSTRUCTORRow(ByVal FORM_TITLE As String, ByVal SEQUENCE_MENU As Integer, ByVal ADDED_WHO As String, ByVal ADDED_WHEN As Date, ByVal CHANGED_WHO As String, ByVal CHANGED_WHEN As Date, ByVal MENU_IMG() As Byte, ByVal SHORT_TITLE As String, ByVal LANGUAGE As String) As TBPMO_FORM_CONSTRUCTORRow
Public Overloads Function AddTBPMO_FORM_CONSTRUCTORRow(ByVal FORM_TITLE As String, ByVal SEQUENCE_MENU As Integer, ByVal ADDED_WHO As String, ByVal ADDED_WHEN As Date, ByVal CHANGED_WHO As String, ByVal CHANGED_WHEN As Date, ByVal MENU_IMG() As Byte, ByVal SHORT_TITLE As String, ByVal LANGUAGE As String, ByVal NODE_NAVIGATION As Boolean) As TBPMO_FORM_CONSTRUCTORRow
Dim rowTBPMO_FORM_CONSTRUCTORRow As TBPMO_FORM_CONSTRUCTORRow = CType(Me.NewRow,TBPMO_FORM_CONSTRUCTORRow)
Dim columnValuesArray() As Object = New Object() {Nothing, FORM_TITLE, SEQUENCE_MENU, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, MENU_IMG, SHORT_TITLE, LANGUAGE}
Dim columnValuesArray() As Object = New Object() {Nothing, FORM_TITLE, SEQUENCE_MENU, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, MENU_IMG, SHORT_TITLE, LANGUAGE, NODE_NAVIGATION}
rowTBPMO_FORM_CONSTRUCTORRow.ItemArray = columnValuesArray
Me.Rows.Add(rowTBPMO_FORM_CONSTRUCTORRow)
Return rowTBPMO_FORM_CONSTRUCTORRow
@@ -1101,6 +1111,7 @@ Partial Public Class DD_ECMAdmin
Me.columnMENU_IMG = MyBase.Columns("MENU_IMG")
Me.columnSHORT_TITLE = MyBase.Columns("SHORT_TITLE")
Me.columnLANGUAGE = MyBase.Columns("LANGUAGE")
Me.columnNODE_NAVIGATION = MyBase.Columns("NODE_NAVIGATION")
End Sub
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
@@ -1126,6 +1137,8 @@ Partial Public Class DD_ECMAdmin
MyBase.Columns.Add(Me.columnSHORT_TITLE)
Me.columnLANGUAGE = New Global.System.Data.DataColumn("LANGUAGE", GetType(String), Nothing, Global.System.Data.MappingType.Element)
MyBase.Columns.Add(Me.columnLANGUAGE)
Me.columnNODE_NAVIGATION = New Global.System.Data.DataColumn("NODE_NAVIGATION", GetType(Boolean), Nothing, Global.System.Data.MappingType.Element)
MyBase.Columns.Add(Me.columnNODE_NAVIGATION)
Me.Constraints.Add(New Global.System.Data.UniqueConstraint("Constraint1", New Global.System.Data.DataColumn() {Me.columnGUID}, true))
Me.columnGUID.AutoIncrement = true
Me.columnGUID.AllowDBNull = false
@@ -1133,11 +1146,15 @@ Partial Public Class DD_ECMAdmin
Me.columnGUID.Unique = true
Me.columnFORM_TITLE.MaxLength = 50
Me.columnSEQUENCE_MENU.AllowDBNull = false
Me.columnADDED_WHO.AllowDBNull = false
Me.columnADDED_WHO.MaxLength = 50
Me.columnADDED_WHEN.AllowDBNull = false
Me.columnCHANGED_WHO.MaxLength = 50
Me.columnSHORT_TITLE.MaxLength = 50
Me.columnLANGUAGE.AllowDBNull = false
Me.columnLANGUAGE.MaxLength = 5
Me.columnNODE_NAVIGATION.AllowDBNull = false
Me.columnNODE_NAVIGATION.DefaultValue = CType(true,Boolean)
End Sub
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
@@ -7711,11 +7728,7 @@ Partial Public Class DD_ECMAdmin
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Property ADDED_WHO() As String
Get
Try
Return CType(Me(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHOColumn),String)
Catch e As Global.System.InvalidCastException
Throw New Global.System.Data.StrongTypingException("Der Wert für Spalte ADDED_WHO in Tabelle TBPMO_FORM_CONSTRUCTOR ist DBNull.", e)
End Try
Return CType(Me(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHOColumn),String)
End Get
Set
Me(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHOColumn) = value
@@ -7726,11 +7739,7 @@ Partial Public Class DD_ECMAdmin
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Property ADDED_WHEN() As Date
Get
Try
Return CType(Me(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHENColumn),Date)
Catch e As Global.System.InvalidCastException
Throw New Global.System.Data.StrongTypingException("Der Wert für Spalte ADDED_WHEN in Tabelle TBPMO_FORM_CONSTRUCTOR ist DBNull.", e)
End Try
Return CType(Me(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHENColumn),Date)
End Get
Set
Me(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHENColumn) = value
@@ -7808,6 +7817,17 @@ Partial Public Class DD_ECMAdmin
End Set
End Property
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Property NODE_NAVIGATION() As Boolean
Get
Return CType(Me(Me.tableTBPMO_FORM_CONSTRUCTOR.NODE_NAVIGATIONColumn),Boolean)
End Get
Set
Me(Me.tableTBPMO_FORM_CONSTRUCTOR.NODE_NAVIGATIONColumn) = value
End Set
End Property
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Function IsFORM_TITLENull() As Boolean
@@ -7820,30 +7840,6 @@ Partial Public Class DD_ECMAdmin
Me(Me.tableTBPMO_FORM_CONSTRUCTOR.FORM_TITLEColumn) = Global.System.Convert.DBNull
End Sub
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Function IsADDED_WHONull() As Boolean
Return Me.IsNull(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHOColumn)
End Function
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Sub SetADDED_WHONull()
Me(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHOColumn) = Global.System.Convert.DBNull
End Sub
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Function IsADDED_WHENNull() As Boolean
Return Me.IsNull(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHENColumn)
End Function
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Sub SetADDED_WHENNull()
Me(Me.tableTBPMO_FORM_CONSTRUCTOR.ADDED_WHENColumn) = Global.System.Convert.DBNull
End Sub
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
Public Function IsCHANGED_WHONull() As Boolean
@@ -11802,6 +11798,7 @@ Namespace DD_ECMAdminTableAdapters
tableMapping.ColumnMappings.Add("MENU_IMG", "MENU_IMG")
tableMapping.ColumnMappings.Add("SHORT_TITLE", "SHORT_TITLE")
tableMapping.ColumnMappings.Add("LANGUAGE", "LANGUAGE")
tableMapping.ColumnMappings.Add("NODE_NAVIGATION", "NODE_NAVIGATION")
Me._adapter.TableMappings.Add(tableMapping)
Me._adapter.DeleteCommand = New Global.System.Data.SqlClient.SqlCommand()
Me._adapter.DeleteCommand.Connection = Me.Connection
@@ -11811,10 +11808,11 @@ Namespace DD_ECMAdminTableAdapters
Me._adapter.InsertCommand = New Global.System.Data.SqlClient.SqlCommand()
Me._adapter.InsertCommand.Connection = Me.Connection
Me._adapter.InsertCommand.CommandText = "INSERT INTO TBPMO_FORM_CONSTRUCTOR"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" (FORM_TITLE, SEQUENC"& _
"E_MENU, ADDED_WHO, MENU_IMG, SHORT_TITLE, LANGUAGE)"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"VALUES (@FORM_TITLE,"& _
"@SEQUENCE_MENU,@ADDED_WHO,@MENU_IMG,@SHORT_TITLE,@LANGUAGE); "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SELECT GUID, FOR"& _
"M_TITLE, SEQUENCE_MENU, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, MENU_I"& _
"MG, SHORT_TITLE FROM TBPMO_FORM_CONSTRUCTOR WHERE (GUID = SCOPE_IDENTITY())"
"E_MENU, ADDED_WHO, MENU_IMG, SHORT_TITLE, LANGUAGE, NODE_NAVIGATION)"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"VALUES "& _
" (@FORM_TITLE,@SEQUENCE_MENU,@ADDED_WHO,@MENU_IMG,@SHORT_TITLE,@LANGUAGE,@NOD"& _
"E_NAVIGATION); "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SELECT GUID, FORM_TITLE, SEQUENCE_MENU, ADDED_WHO, ADDED_WHEN"& _
", CHANGED_WHO, CHANGED_WHEN, MENU_IMG, SHORT_TITLE FROM TBPMO_FORM_CONSTRUCTOR W"& _
"HERE (GUID = SCOPE_IDENTITY())"
Me._adapter.InsertCommand.CommandType = Global.System.Data.CommandType.Text
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@FORM_TITLE", Global.System.Data.SqlDbType.VarChar, 50, Global.System.Data.ParameterDirection.Input, 0, 0, "FORM_TITLE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SEQUENCE_MENU", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "SEQUENCE_MENU", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
@@ -11822,14 +11820,15 @@ Namespace DD_ECMAdminTableAdapters
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@MENU_IMG", Global.System.Data.SqlDbType.VarBinary, 2147483647, Global.System.Data.ParameterDirection.Input, 0, 0, "MENU_IMG", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SHORT_TITLE", Global.System.Data.SqlDbType.VarChar, 50, Global.System.Data.ParameterDirection.Input, 0, 0, "SHORT_TITLE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@LANGUAGE", Global.System.Data.SqlDbType.VarChar, 5, Global.System.Data.ParameterDirection.Input, 0, 0, "LANGUAGE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@NODE_NAVIGATION", Global.System.Data.SqlDbType.Bit, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "NODE_NAVIGATION", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.UpdateCommand = New Global.System.Data.SqlClient.SqlCommand()
Me._adapter.UpdateCommand.Connection = Me.Connection
Me._adapter.UpdateCommand.CommandText = "UPDATE TBPMO_FORM_CONSTRUCTOR"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SET FORM_TITLE = @FORM_TITLE,"& _
" SEQUENCE_MENU = @SEQUENCE_MENU, CHANGED_WHO = @CHANGED_WHO, MENU_IMG = @MENU_IM"& _
"G, SHORT_TITLE = @SHORT_TITLE, "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" LANGUAGE = @LANGUAGE"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)& _
"WHERE (GUID = @Original_GUID); "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SELECT GUID, FORM_TITLE, SEQUENCE_MENU"& _
", ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, MENU_IMG, SHORT_TITLE FROM T"& _
"BPMO_FORM_CONSTRUCTOR WHERE (GUID = @GUID)"
"G, SHORT_TITLE = @SHORT_TITLE, LANGUAGE = @LANGUAGE, "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" "& _
"NODE_NAVIGATION = @NODE_NAVIGATION"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"WHERE (GUID = @Original_GUID); "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"S"& _
"ELECT GUID, FORM_TITLE, SEQUENCE_MENU, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANG"& _
"ED_WHEN, MENU_IMG, SHORT_TITLE FROM TBPMO_FORM_CONSTRUCTOR WHERE (GUID = @GUID)"
Me._adapter.UpdateCommand.CommandType = Global.System.Data.CommandType.Text
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@FORM_TITLE", Global.System.Data.SqlDbType.VarChar, 50, Global.System.Data.ParameterDirection.Input, 0, 0, "FORM_TITLE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SEQUENCE_MENU", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "SEQUENCE_MENU", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
@@ -11837,6 +11836,7 @@ Namespace DD_ECMAdminTableAdapters
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@MENU_IMG", Global.System.Data.SqlDbType.VarBinary, 2147483647, Global.System.Data.ParameterDirection.Input, 0, 0, "MENU_IMG", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SHORT_TITLE", Global.System.Data.SqlDbType.VarChar, 50, Global.System.Data.ParameterDirection.Input, 0, 0, "SHORT_TITLE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@LANGUAGE", Global.System.Data.SqlDbType.VarChar, 5, Global.System.Data.ParameterDirection.Input, 0, 0, "LANGUAGE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@NODE_NAVIGATION", Global.System.Data.SqlDbType.Bit, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "NODE_NAVIGATION", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@Original_GUID", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "GUID", Global.System.Data.DataRowVersion.Original, false, Nothing, "", "", ""))
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@GUID", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "GUID", Global.System.Data.DataRowVersion.Original, false, Nothing, "", "", ""))
End Sub
@@ -11857,7 +11857,7 @@ Namespace DD_ECMAdminTableAdapters
Me._commandCollection(0).CommandText = "SELECT GUID, dbo.FNPMO_GETOBJECTCAPTION(@LANGUAGE, 'CONSTR_MENUE' + CONVER"& _
"T(VARCHAR(5), GUID), @SCREEN_ID) AS FORM_TITLE, SEQUENCE_MENU, ADDED_WHO, ADDED_"& _
"WHEN, CHANGED_WHO, "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" CHANGED_WHEN, MENU_IMG, SHORT_TITL"& _
"E, LANGUAGE"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"FROM TBPMO_FORM_CONSTRUCTOR"
"E, LANGUAGE, NODE_NAVIGATION"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"FROM TBPMO_FORM_CONSTRUCTOR"
Me._commandCollection(0).CommandType = Global.System.Data.CommandType.Text
Me._commandCollection(0).Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@LANGUAGE", Global.System.Data.SqlDbType.VarChar, 1024, Global.System.Data.ParameterDirection.Input, 0, 0, "", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
Me._commandCollection(0).Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SCREEN_ID", Global.System.Data.SqlDbType.Int, 0, Global.System.Data.ParameterDirection.Input, 0, 0, "", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
@@ -11952,7 +11952,7 @@ Namespace DD_ECMAdminTableAdapters
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0"), _
Global.System.ComponentModel.Design.HelpKeywordAttribute("vs.data.TableAdapter"), _
Global.System.ComponentModel.DataObjectMethodAttribute(Global.System.ComponentModel.DataObjectMethodType.Insert, true)> _
Public Overloads Overridable Function Insert(ByVal FORM_TITLE As String, ByVal SEQUENCE_MENU As Integer, ByVal ADDED_WHO As String, ByVal MENU_IMG() As Byte, ByVal SHORT_TITLE As String, ByVal LANGUAGE As String) As Integer
Public Overloads Overridable Function Insert(ByVal FORM_TITLE As String, ByVal SEQUENCE_MENU As Integer, ByVal ADDED_WHO As String, ByVal MENU_IMG() As Byte, ByVal SHORT_TITLE As String, ByVal LANGUAGE As String, ByVal NODE_NAVIGATION As Boolean) As Integer
If (FORM_TITLE Is Nothing) Then
Me.Adapter.InsertCommand.Parameters(0).Value = Global.System.DBNull.Value
Else
@@ -11979,6 +11979,7 @@ Namespace DD_ECMAdminTableAdapters
Else
Me.Adapter.InsertCommand.Parameters(5).Value = CType(LANGUAGE,String)
End If
Me.Adapter.InsertCommand.Parameters(6).Value = CType(NODE_NAVIGATION,Boolean)
Dim previousConnectionState As Global.System.Data.ConnectionState = Me.Adapter.InsertCommand.Connection.State
If ((Me.Adapter.InsertCommand.Connection.State And Global.System.Data.ConnectionState.Open) _
<> Global.System.Data.ConnectionState.Open) Then
@@ -11998,7 +11999,7 @@ Namespace DD_ECMAdminTableAdapters
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0"), _
Global.System.ComponentModel.Design.HelpKeywordAttribute("vs.data.TableAdapter"), _
Global.System.ComponentModel.DataObjectMethodAttribute(Global.System.ComponentModel.DataObjectMethodType.Update, true)> _
Public Overloads Overridable Function Update(ByVal FORM_TITLE As String, ByVal SEQUENCE_MENU As Integer, ByVal CHANGED_WHO As String, ByVal MENU_IMG() As Byte, ByVal SHORT_TITLE As String, ByVal LANGUAGE As String, ByVal Original_GUID As Integer, ByVal GUID As Integer) As Integer
Public Overloads Overridable Function Update(ByVal FORM_TITLE As String, ByVal SEQUENCE_MENU As Integer, ByVal CHANGED_WHO As String, ByVal MENU_IMG() As Byte, ByVal SHORT_TITLE As String, ByVal LANGUAGE As String, ByVal NODE_NAVIGATION As Boolean, ByVal Original_GUID As Integer, ByVal GUID As Integer) As Integer
If (FORM_TITLE Is Nothing) Then
Me.Adapter.UpdateCommand.Parameters(0).Value = Global.System.DBNull.Value
Else
@@ -12025,8 +12026,9 @@ Namespace DD_ECMAdminTableAdapters
Else
Me.Adapter.UpdateCommand.Parameters(5).Value = CType(LANGUAGE,String)
End If
Me.Adapter.UpdateCommand.Parameters(6).Value = CType(Original_GUID,Integer)
Me.Adapter.UpdateCommand.Parameters(7).Value = CType(GUID,Integer)
Me.Adapter.UpdateCommand.Parameters(6).Value = CType(NODE_NAVIGATION,Boolean)
Me.Adapter.UpdateCommand.Parameters(7).Value = CType(Original_GUID,Integer)
Me.Adapter.UpdateCommand.Parameters(8).Value = CType(GUID,Integer)
Dim previousConnectionState As Global.System.Data.ConnectionState = Me.Adapter.UpdateCommand.Connection.State
If ((Me.Adapter.UpdateCommand.Connection.State And Global.System.Data.ConnectionState.Open) _
<> Global.System.Data.ConnectionState.Open) Then