Add VKT_PREVENT_NEW_VALUES and VKT_OVERWRITE in Dataset
This commit is contained in:
120
Global_Indexer/MyDataset.Designer.vb
generated
120
Global_Indexer/MyDataset.Designer.vb
generated
@@ -5084,6 +5084,10 @@ Partial Public Class MyDataset
|
||||
|
||||
Private columnSEQUENCE As Global.System.Data.DataColumn
|
||||
|
||||
Private columnVKT_PREVENT_MULTIPLE_VALUES As Global.System.Data.DataColumn
|
||||
|
||||
Private columnVKT_OVERWRITE As Global.System.Data.DataColumn
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
|
||||
Public Sub New()
|
||||
@@ -5231,6 +5235,22 @@ Partial Public Class MyDataset
|
||||
End Get
|
||||
End Property
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
|
||||
Public ReadOnly Property VKT_PREVENT_MULTIPLE_VALUESColumn() As Global.System.Data.DataColumn
|
||||
Get
|
||||
Return Me.columnVKT_PREVENT_MULTIPLE_VALUES
|
||||
End Get
|
||||
End Property
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
|
||||
Public ReadOnly Property VKT_OVERWRITEColumn() As Global.System.Data.DataColumn
|
||||
Get
|
||||
Return Me.columnVKT_OVERWRITE
|
||||
End Get
|
||||
End Property
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0"), _
|
||||
Global.System.ComponentModel.Browsable(false)> _
|
||||
@@ -5268,9 +5288,9 @@ Partial Public Class MyDataset
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
|
||||
Public Overloads Function AddTBDD_INDEX_AUTOMRow(ByVal parentTBDD_DOKUMENTARTRowByFK_TBDD_INDEX_AUTOM_DOCID As TBDD_DOKUMENTARTRow, ByVal INDEXNAME As String, ByVal VALUE As String, ByVal CONNECTION_ID As Short, ByVal COMMENT As String, ByVal ACTIVE As Boolean, ByVal ADDED_WHO As String, ByVal ADDED_WHEN As Date, ByVal CHANGED_WHO As String, ByVal CHANGED_WHEN As Date, ByVal SQL_RESULT As String, ByVal SQL_ACTIVE As Boolean, ByVal SEQUENCE As Byte) As TBDD_INDEX_AUTOMRow
|
||||
Public Overloads Function AddTBDD_INDEX_AUTOMRow(ByVal parentTBDD_DOKUMENTARTRowByFK_TBDD_INDEX_AUTOM_DOCID As TBDD_DOKUMENTARTRow, ByVal INDEXNAME As String, ByVal VALUE As String, ByVal CONNECTION_ID As Short, ByVal COMMENT As String, ByVal ACTIVE As Boolean, ByVal ADDED_WHO As String, ByVal ADDED_WHEN As Date, ByVal CHANGED_WHO As String, ByVal CHANGED_WHEN As Date, ByVal SQL_RESULT As String, ByVal SQL_ACTIVE As Boolean, ByVal SEQUENCE As Byte, ByVal VKT_PREVENT_MULTIPLE_VALUES As Boolean, ByVal VKT_OVERWRITE As Boolean) As TBDD_INDEX_AUTOMRow
|
||||
Dim rowTBDD_INDEX_AUTOMRow As TBDD_INDEX_AUTOMRow = CType(Me.NewRow,TBDD_INDEX_AUTOMRow)
|
||||
Dim columnValuesArray() As Object = New Object() {Nothing, Nothing, INDEXNAME, VALUE, CONNECTION_ID, COMMENT, ACTIVE, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, SQL_RESULT, SQL_ACTIVE, SEQUENCE}
|
||||
Dim columnValuesArray() As Object = New Object() {Nothing, Nothing, INDEXNAME, VALUE, CONNECTION_ID, COMMENT, ACTIVE, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, SQL_RESULT, SQL_ACTIVE, SEQUENCE, VKT_PREVENT_MULTIPLE_VALUES, VKT_OVERWRITE}
|
||||
If (Not (parentTBDD_DOKUMENTARTRowByFK_TBDD_INDEX_AUTOM_DOCID) Is Nothing) Then
|
||||
columnValuesArray(1) = parentTBDD_DOKUMENTARTRowByFK_TBDD_INDEX_AUTOM_DOCID(0)
|
||||
End If
|
||||
@@ -5316,6 +5336,8 @@ Partial Public Class MyDataset
|
||||
Me.columnSQL_RESULT = MyBase.Columns("SQL_RESULT")
|
||||
Me.columnSQL_ACTIVE = MyBase.Columns("SQL_ACTIVE")
|
||||
Me.columnSEQUENCE = MyBase.Columns("SEQUENCE")
|
||||
Me.columnVKT_PREVENT_MULTIPLE_VALUES = MyBase.Columns("VKT_PREVENT_MULTIPLE_VALUES")
|
||||
Me.columnVKT_OVERWRITE = MyBase.Columns("VKT_OVERWRITE")
|
||||
End Sub
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
@@ -5349,6 +5371,10 @@ Partial Public Class MyDataset
|
||||
MyBase.Columns.Add(Me.columnSQL_ACTIVE)
|
||||
Me.columnSEQUENCE = New Global.System.Data.DataColumn("SEQUENCE", GetType(Byte), Nothing, Global.System.Data.MappingType.Element)
|
||||
MyBase.Columns.Add(Me.columnSEQUENCE)
|
||||
Me.columnVKT_PREVENT_MULTIPLE_VALUES = New Global.System.Data.DataColumn("VKT_PREVENT_MULTIPLE_VALUES", GetType(Boolean), Nothing, Global.System.Data.MappingType.Element)
|
||||
MyBase.Columns.Add(Me.columnVKT_PREVENT_MULTIPLE_VALUES)
|
||||
Me.columnVKT_OVERWRITE = New Global.System.Data.DataColumn("VKT_OVERWRITE", GetType(Boolean), Nothing, Global.System.Data.MappingType.Element)
|
||||
MyBase.Columns.Add(Me.columnVKT_OVERWRITE)
|
||||
Me.Constraints.Add(New Global.System.Data.UniqueConstraint("Constraint1", New Global.System.Data.DataColumn() {Me.columnGUID}, true))
|
||||
Me.columnGUID.AutoIncrement = true
|
||||
Me.columnGUID.AllowDBNull = false
|
||||
@@ -5374,6 +5400,10 @@ Partial Public Class MyDataset
|
||||
Me.columnSQL_ACTIVE.DefaultValue = CType(false,Boolean)
|
||||
Me.columnSEQUENCE.AllowDBNull = false
|
||||
Me.columnSEQUENCE.DefaultValue = CType(0,Byte)
|
||||
Me.columnVKT_PREVENT_MULTIPLE_VALUES.AllowDBNull = false
|
||||
Me.columnVKT_PREVENT_MULTIPLE_VALUES.DefaultValue = CType(false,Boolean)
|
||||
Me.columnVKT_OVERWRITE.AllowDBNull = false
|
||||
Me.columnVKT_OVERWRITE.DefaultValue = CType(false,Boolean)
|
||||
End Sub
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
@@ -12306,6 +12336,28 @@ Partial Public Class MyDataset
|
||||
End Set
|
||||
End Property
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
|
||||
Public Property VKT_PREVENT_MULTIPLE_VALUES() As Boolean
|
||||
Get
|
||||
Return CType(Me(Me.tableTBDD_INDEX_AUTOM.VKT_PREVENT_MULTIPLE_VALUESColumn),Boolean)
|
||||
End Get
|
||||
Set
|
||||
Me(Me.tableTBDD_INDEX_AUTOM.VKT_PREVENT_MULTIPLE_VALUESColumn) = value
|
||||
End Set
|
||||
End Property
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
|
||||
Public Property VKT_OVERWRITE() As Boolean
|
||||
Get
|
||||
Return CType(Me(Me.tableTBDD_INDEX_AUTOM.VKT_OVERWRITEColumn),Boolean)
|
||||
End Get
|
||||
Set
|
||||
Me(Me.tableTBDD_INDEX_AUTOM.VKT_OVERWRITEColumn) = value
|
||||
End Set
|
||||
End Property
|
||||
|
||||
<Global.System.Diagnostics.DebuggerNonUserCodeAttribute(), _
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0")> _
|
||||
Public Property TBDD_DOKUMENTARTRow() As TBDD_DOKUMENTARTRow
|
||||
@@ -18195,6 +18247,8 @@ Namespace MyDatasetTableAdapters
|
||||
tableMapping.ColumnMappings.Add("SQL_RESULT", "SQL_RESULT")
|
||||
tableMapping.ColumnMappings.Add("SQL_ACTIVE", "SQL_ACTIVE")
|
||||
tableMapping.ColumnMappings.Add("SEQUENCE", "SEQUENCE")
|
||||
tableMapping.ColumnMappings.Add("VKT_PREVENT_MULTIPLE_VALUES", "VKT_PREVENT_MULTIPLE_VALUES")
|
||||
tableMapping.ColumnMappings.Add("VKT_OVERWRITE", "VKT_OVERWRITE")
|
||||
Me._adapter.TableMappings.Add(tableMapping)
|
||||
Me._adapter.DeleteCommand = New Global.System.Data.SqlClient.SqlCommand()
|
||||
Me._adapter.DeleteCommand.Connection = Me.Connection
|
||||
@@ -18232,12 +18286,13 @@ Namespace MyDatasetTableAdapters
|
||||
Me._adapter.InsertCommand.Connection = Me.Connection
|
||||
Me._adapter.InsertCommand.CommandText = "INSERT INTO TBDD_INDEX_AUTOM"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" (DOCTYPE_ID, INDEXNAME, VA"& _
|
||||
"LUE, CONNECTION_ID, COMMENT, ACTIVE, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED"& _
|
||||
"_WHEN, SQL_RESULT, SQL_ACTIVE, SEQUENCE)"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"VALUES (@DOCTYPE_ID,@INDEXNAME,"& _
|
||||
"@VALUE,@CONNECTION_ID,@COMMENT,@ACTIVE,@ADDED_WHO,@ADDED_WHEN,@CHANGED_WHO,@CHAN"& _
|
||||
"GED_WHEN,@SQL_RESULT,@SQL_ACTIVE,@SEQUENCE); "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SELECT GUID, DOCTYPE_ID, INDEXNAM"& _
|
||||
"E, VALUE, CONNECTION_ID, COMMENT, ACTIVE, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CH"& _
|
||||
"ANGED_WHEN, SQL_RESULT, SQL_ACTIVE FROM TBDD_INDEX_AUTOM WHERE (GUID = SCOPE_IDE"& _
|
||||
"NTITY()) ORDER BY SEQUENCE"
|
||||
"_WHEN, SQL_RESULT, SQL_ACTIVE, SEQUENCE, VKT_PREVENT_MULTIPLE_VALUES, "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" "& _
|
||||
" VKT_OVERWRITE)"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"VALUES (@DOCTYPE_ID,@INDEXNAME,@VALUE,@C"& _
|
||||
"ONNECTION_ID,@COMMENT,@ACTIVE,@ADDED_WHO,@ADDED_WHEN,@CHANGED_WHO,@CHANGED_WHEN,"& _
|
||||
"@SQL_RESULT,@SQL_ACTIVE,@SEQUENCE,@VKT_PREVENT_MULTIPLE_VALUES,@VKT_OVERWRITE); "& _
|
||||
" "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SELECT GUID, DOCTYPE_ID, INDEXNAME, VALUE, CONNECTION_ID, COMMENT, ACTIVE, AD"& _
|
||||
"DED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, SQL_RESULT, SQL_ACTIVE FROM TBDD"& _
|
||||
"_INDEX_AUTOM WHERE (GUID = SCOPE_IDENTITY()) ORDER BY SEQUENCE"
|
||||
Me._adapter.InsertCommand.CommandType = Global.System.Data.CommandType.Text
|
||||
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@DOCTYPE_ID", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "DOCTYPE_ID", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@INDEXNAME", Global.System.Data.SqlDbType.VarChar, 50, Global.System.Data.ParameterDirection.Input, 0, 0, "INDEXNAME", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
@@ -18252,17 +18307,20 @@ Namespace MyDatasetTableAdapters
|
||||
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SQL_RESULT", Global.System.Data.SqlDbType.VarChar, 2000, Global.System.Data.ParameterDirection.Input, 0, 0, "SQL_RESULT", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SQL_ACTIVE", Global.System.Data.SqlDbType.Bit, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "SQL_ACTIVE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SEQUENCE", Global.System.Data.SqlDbType.TinyInt, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "SEQUENCE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@VKT_PREVENT_MULTIPLE_VALUES", Global.System.Data.SqlDbType.Bit, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "VKT_PREVENT_MULTIPLE_VALUES", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.InsertCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@VKT_OVERWRITE", Global.System.Data.SqlDbType.Bit, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "VKT_OVERWRITE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.UpdateCommand = New Global.System.Data.SqlClient.SqlCommand()
|
||||
Me._adapter.UpdateCommand.Connection = Me.Connection
|
||||
Me._adapter.UpdateCommand.CommandText = "UPDATE TBDD_INDEX_AUTOM"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SET DOCTYPE_ID = @DOCTYPE_ID, INDEX"& _
|
||||
"NAME = @INDEXNAME, VALUE = @VALUE, CONNECTION_ID = @CONNECTION_ID, COMMENT = @CO"& _
|
||||
"MMENT, ACTIVE = @ACTIVE, ADDED_WHO = @ADDED_WHO, "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" ADDE"& _
|
||||
"D_WHEN = @ADDED_WHEN, CHANGED_WHO = @CHANGED_WHO, CHANGED_WHEN = @CHANGED_WHEN, "& _
|
||||
"SQL_RESULT = @SQL_RESULT, SQL_ACTIVE = @SQL_ACTIVE, SEQUENCE = @SEQUENCE"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"WHERE "& _
|
||||
" (GUID = @Original_GUID); "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SELECT GUID, DOCTYPE_ID, INDEXNAME, VALUE, CON"& _
|
||||
"NECTION_ID, COMMENT, ACTIVE, ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, S"& _
|
||||
"QL_RESULT, SQL_ACTIVE FROM TBDD_INDEX_AUTOM WHERE (GUID = @GUID) ORDER BY SEQUEN"& _
|
||||
"CE"
|
||||
"SQL_RESULT = @SQL_RESULT, SQL_ACTIVE = @SQL_ACTIVE, SEQUENCE = @SEQUENCE, "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" "& _
|
||||
" VKT_PREVENT_MULTIPLE_VALUES = @VKT_PREVENT_MULTIPLE_VALUES,"& _
|
||||
" VKT_OVERWRITE = @VKT_OVERWRITE"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"WHERE (GUID = @Original_GUID); "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"SELECT"& _
|
||||
" GUID, DOCTYPE_ID, INDEXNAME, VALUE, CONNECTION_ID, COMMENT, ACTIVE, ADDED_WHO, "& _
|
||||
"ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, SQL_RESULT, SQL_ACTIVE FROM TBDD_INDEX_AU"& _
|
||||
"TOM WHERE (GUID = @GUID) ORDER BY SEQUENCE"
|
||||
Me._adapter.UpdateCommand.CommandType = Global.System.Data.CommandType.Text
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@DOCTYPE_ID", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "DOCTYPE_ID", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@INDEXNAME", Global.System.Data.SqlDbType.VarChar, 50, Global.System.Data.ParameterDirection.Input, 0, 0, "INDEXNAME", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
@@ -18277,6 +18335,8 @@ Namespace MyDatasetTableAdapters
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SQL_RESULT", Global.System.Data.SqlDbType.VarChar, 2000, Global.System.Data.ParameterDirection.Input, 0, 0, "SQL_RESULT", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SQL_ACTIVE", Global.System.Data.SqlDbType.Bit, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "SQL_ACTIVE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@SEQUENCE", Global.System.Data.SqlDbType.TinyInt, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "SEQUENCE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@VKT_PREVENT_MULTIPLE_VALUES", Global.System.Data.SqlDbType.Bit, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "VKT_PREVENT_MULTIPLE_VALUES", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@VKT_OVERWRITE", Global.System.Data.SqlDbType.Bit, 1, Global.System.Data.ParameterDirection.Input, 0, 0, "VKT_OVERWRITE", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@Original_GUID", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "GUID", Global.System.Data.DataRowVersion.Original, false, Nothing, "", "", ""))
|
||||
Me._adapter.UpdateCommand.Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@GUID", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "GUID", Global.System.Data.DataRowVersion.Original, false, Nothing, "", "", ""))
|
||||
End Sub
|
||||
@@ -18296,8 +18356,9 @@ Namespace MyDatasetTableAdapters
|
||||
Me._commandCollection(0).Connection = Me.Connection
|
||||
Me._commandCollection(0).CommandText = "SELECT GUID, DOCTYPE_ID, INDEXNAME, VALUE, CONNECTION_ID, COMMENT, ACTIVE,"& _
|
||||
" ADDED_WHO, ADDED_WHEN, CHANGED_WHO, CHANGED_WHEN, SQL_RESULT, SQL_ACTIVE, SEQUE"& _
|
||||
"NCE"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"FROM TBDD_INDEX_AUTOM"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"WHERE (DOCTYPE_ID = @DOCTYPE_ID)"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)& _
|
||||
"ORDER BY SEQUENCE"
|
||||
"NCE, "&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&" VKT_PREVENT_MULTIPLE_VALUES, VKT_OVERWRITE"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"FROM"& _
|
||||
" TBDD_INDEX_AUTOM"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"WHERE (DOCTYPE_ID = @DOCTYPE_ID)"&Global.Microsoft.VisualBasic.ChrW(13)&Global.Microsoft.VisualBasic.ChrW(10)&"ORDER BY "& _
|
||||
"SEQUENCE"
|
||||
Me._commandCollection(0).CommandType = Global.System.Data.CommandType.Text
|
||||
Me._commandCollection(0).Parameters.Add(New Global.System.Data.SqlClient.SqlParameter("@DOCTYPE_ID", Global.System.Data.SqlDbType.Int, 4, Global.System.Data.ParameterDirection.Input, 0, 0, "DOCTYPE_ID", Global.System.Data.DataRowVersion.Current, false, Nothing, "", "", ""))
|
||||
End Sub
|
||||
@@ -18435,7 +18496,7 @@ Namespace MyDatasetTableAdapters
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0"), _
|
||||
Global.System.ComponentModel.Design.HelpKeywordAttribute("vs.data.TableAdapter"), _
|
||||
Global.System.ComponentModel.DataObjectMethodAttribute(Global.System.ComponentModel.DataObjectMethodType.Insert, true)> _
|
||||
Public Overloads Overridable Function Insert(ByVal DOCTYPE_ID As Integer, ByVal INDEXNAME As String, ByVal VALUE As String, ByVal CONNECTION_ID As Short, ByVal COMMENT As String, ByVal ACTIVE As Boolean, ByVal ADDED_WHO As String, ByVal ADDED_WHEN As Global.System.Nullable(Of Date), ByVal CHANGED_WHO As String, ByVal CHANGED_WHEN As Global.System.Nullable(Of Date), ByVal SQL_RESULT As String, ByVal SQL_ACTIVE As Boolean, ByVal SEQUENCE As Byte) As Integer
|
||||
Public Overloads Overridable Function Insert(ByVal DOCTYPE_ID As Integer, ByVal INDEXNAME As String, ByVal VALUE As String, ByVal CONNECTION_ID As Short, ByVal COMMENT As String, ByVal ACTIVE As Boolean, ByVal ADDED_WHO As String, ByVal ADDED_WHEN As Global.System.Nullable(Of Date), ByVal CHANGED_WHO As String, ByVal CHANGED_WHEN As Global.System.Nullable(Of Date), ByVal SQL_RESULT As String, ByVal SQL_ACTIVE As Boolean, ByVal SEQUENCE As Byte, ByVal VKT_PREVENT_MULTIPLE_VALUES As Boolean, ByVal VKT_OVERWRITE As Boolean) As Integer
|
||||
Me.Adapter.InsertCommand.Parameters(0).Value = CType(DOCTYPE_ID,Integer)
|
||||
If (INDEXNAME Is Nothing) Then
|
||||
Throw New Global.System.ArgumentNullException("INDEXNAME")
|
||||
@@ -18481,6 +18542,8 @@ Namespace MyDatasetTableAdapters
|
||||
End If
|
||||
Me.Adapter.InsertCommand.Parameters(11).Value = CType(SQL_ACTIVE,Boolean)
|
||||
Me.Adapter.InsertCommand.Parameters(12).Value = CType(SEQUENCE,Byte)
|
||||
Me.Adapter.InsertCommand.Parameters(13).Value = CType(VKT_PREVENT_MULTIPLE_VALUES,Boolean)
|
||||
Me.Adapter.InsertCommand.Parameters(14).Value = CType(VKT_OVERWRITE,Boolean)
|
||||
Dim previousConnectionState As Global.System.Data.ConnectionState = Me.Adapter.InsertCommand.Connection.State
|
||||
If ((Me.Adapter.InsertCommand.Connection.State And Global.System.Data.ConnectionState.Open) _
|
||||
<> Global.System.Data.ConnectionState.Open) Then
|
||||
@@ -18500,7 +18563,24 @@ Namespace MyDatasetTableAdapters
|
||||
Global.System.CodeDom.Compiler.GeneratedCodeAttribute("System.Data.Design.TypedDataSetGenerator", "17.0.0.0"), _
|
||||
Global.System.ComponentModel.Design.HelpKeywordAttribute("vs.data.TableAdapter"), _
|
||||
Global.System.ComponentModel.DataObjectMethodAttribute(Global.System.ComponentModel.DataObjectMethodType.Update, true)> _
|
||||
Public Overloads Overridable Function Update(ByVal DOCTYPE_ID As Integer, ByVal INDEXNAME As String, ByVal VALUE As String, ByVal CONNECTION_ID As Short, ByVal COMMENT As String, ByVal ACTIVE As Boolean, ByVal ADDED_WHO As String, ByVal ADDED_WHEN As Global.System.Nullable(Of Date), ByVal CHANGED_WHO As String, ByVal CHANGED_WHEN As Global.System.Nullable(Of Date), ByVal SQL_RESULT As String, ByVal SQL_ACTIVE As Boolean, ByVal SEQUENCE As Byte, ByVal Original_GUID As Integer, ByVal GUID As Integer) As Integer
|
||||
Public Overloads Overridable Function Update( _
|
||||
ByVal DOCTYPE_ID As Integer, _
|
||||
ByVal INDEXNAME As String, _
|
||||
ByVal VALUE As String, _
|
||||
ByVal CONNECTION_ID As Short, _
|
||||
ByVal COMMENT As String, _
|
||||
ByVal ACTIVE As Boolean, _
|
||||
ByVal ADDED_WHO As String, _
|
||||
ByVal ADDED_WHEN As Global.System.Nullable(Of Date), _
|
||||
ByVal CHANGED_WHO As String, _
|
||||
ByVal CHANGED_WHEN As Global.System.Nullable(Of Date), _
|
||||
ByVal SQL_RESULT As String, _
|
||||
ByVal SQL_ACTIVE As Boolean, _
|
||||
ByVal SEQUENCE As Byte, _
|
||||
ByVal VKT_PREVENT_MULTIPLE_VALUES As Boolean, _
|
||||
ByVal VKT_OVERWRITE As Boolean, _
|
||||
ByVal Original_GUID As Integer, _
|
||||
ByVal GUID As Integer) As Integer
|
||||
Me.Adapter.UpdateCommand.Parameters(0).Value = CType(DOCTYPE_ID,Integer)
|
||||
If (INDEXNAME Is Nothing) Then
|
||||
Throw New Global.System.ArgumentNullException("INDEXNAME")
|
||||
@@ -18546,8 +18626,10 @@ Namespace MyDatasetTableAdapters
|
||||
End If
|
||||
Me.Adapter.UpdateCommand.Parameters(11).Value = CType(SQL_ACTIVE,Boolean)
|
||||
Me.Adapter.UpdateCommand.Parameters(12).Value = CType(SEQUENCE,Byte)
|
||||
Me.Adapter.UpdateCommand.Parameters(13).Value = CType(Original_GUID,Integer)
|
||||
Me.Adapter.UpdateCommand.Parameters(14).Value = CType(GUID,Integer)
|
||||
Me.Adapter.UpdateCommand.Parameters(13).Value = CType(VKT_PREVENT_MULTIPLE_VALUES,Boolean)
|
||||
Me.Adapter.UpdateCommand.Parameters(14).Value = CType(VKT_OVERWRITE,Boolean)
|
||||
Me.Adapter.UpdateCommand.Parameters(15).Value = CType(Original_GUID,Integer)
|
||||
Me.Adapter.UpdateCommand.Parameters(16).Value = CType(GUID,Integer)
|
||||
Dim previousConnectionState As Global.System.Data.ConnectionState = Me.Adapter.UpdateCommand.Connection.State
|
||||
If ((Me.Adapter.UpdateCommand.Connection.State And Global.System.Data.ConnectionState.Open) _
|
||||
<> Global.System.Data.ConnectionState.Open) Then
|
||||
|
||||
Reference in New Issue
Block a user